LIQUID GASES
753


for some time into the charcoal cooled in liquid air. On exposure to the electric beam the vanes began to spin, but soon ceased when the bulb A was cooled in liquid air. When, however, the mercury was warmed by placing the bulb in liquid water, the vanes began to move again, and in the particular radiometer used this was found to happen when the temperature of the mercury had risen to −23° C. corresponding to a pressure of about one fifty-millionth of an atmosphere.

For washing out the radiometer with oxygen the arrangement shown in fig. 7 is convenient. Here A is a bulb containing perchlorate of potash, which when heated gives off pure oxygen; C is again the radiometer and B the charcoal bulb. The side tube E is for the purpose of examining the gas given off by minerals like thorianite or the gaseous products of the transformation of radioactive bodies.

Fig. 7.

Analytic Uses.—Another important use of liquid gases is as analytic agents, and for this purpose liquid air is becoming an almost essential laboratory reagent. It is one of the most convenient agents for drying gases and for their purification. If a mixture of gases be subjected to the temperature of liquid air, it is obvious that all the constituents that are more condensable than air will be reduced to liquid, while those that are less condensable will either remain as a gaseous residue or be dissolved in the liquid obtained. The bodies present in the latter may be separated by fractional distillation, while the contents of the gaseous residue may be further differentiated by the air of still lower temperatures, such as are obtainable by liquid hydrogen. An apparatus such as the following can be used to separate both the less and the more volatile gases of the atmosphere, the former being obtained from their solution in liquid air by fractional distillation at low pressure and separation of the condensable part of the distillate by cooling in liquid hydrogen, while the latter are extracted from the residue of liquid air, after the distillation of the first fraction, by allowing it to evaporate gradually at a temperature rising only very slowly.

In fig. 8, A represents a vacuum-jacketed vessel, containing liquid air; this can be made to boil at reduced pressure and therefore be lowered in temperature by means of an air-pump, which is in communication with the vessel through the pipe s. The liquid boiled away is replenished when necessary from the reservoir C, p being a valve, worked by handle q, by which the flow along r is regulated. The vessel B, immersed in the liquid air of A, communicates with the atmosphere by a; hence when the temperature of A falls under exhaustion below that of liquid air, the contents of B condense, and if the stop-cock m is kept open, and n shut, air from the outside is continuously sucked in until B is full of liquid, which contains in solution the whole of the most volatile gases of the atmosphere which have passed in through a. At this stage of the operation m is closed and n opened, a passage thus being opened along b from A to the remainder of the apparatus seen on the left side of the figure. Here E is a vacuum vessel containing liquid hydrogen, and d a three-way cock by which communication can be established either between b and D, between b and e, the tube leading to the sparking-tube g, or between D and e. If now d is arranged so that there is a free passage from b to D, and the stop-cock n also opened, the gas dissolved in the liquid in B, together with some of the most volatile part of that liquid, quickly distils over into D, which is at a much lower temperature than B, and some of it condenses there in the solid state. When a small fraction of the contents of B has thus distilled over, d is turned so as to close the passage between D and b and open that between D and e, with the result that the gas in D is pumped out by the mercury-pump, shown diagrammatically at F, along the tube e (which is immersed in the liquid hydrogen in order that any more condensable gas carried along by the current may be frozen out) to the sparking-tube or tubes g, where it can be examined spectroscopically. When the apparatus is used to separate the least volatile part of the gases in the atmosphere, the vessel E and its contents are omitted, and the tube b made to communicate with the pump through a number of sparking-tubes which can be sealed off successively. The nitrogen and oxygen which make up the bulk of the liquid in B are allowed to evaporate gradually, the temperature being kept low so as to check the evaporation of gases less volatile than oxygen. When most of the oxygen and nitrogen have thus been removed, the stop-cock n is closed, and the tubes partially exhausted by the pump; spectroscopic examination is made of the gases they contain, and repeated from time to time as more gas is allowed to evaporate from B. The general sequence of spectra, apart from those of nitrogen, oxygen and carbon compounds, which are never eliminated by the process of distillation alone, is as follows: The spectrum of argon first appears, followed by the brightest (green and yellow) rays of krypton. Then the intensity of the argon spectrum wanes and it gives way to that of krypton, until, as Runge observed, when a Leyden jar is in the circuit, the capillary part of the sparking-tube has a magnificent blue colour, while the wide ends are bright pale yellow. Without a jar the tube is nearly white in the middle and yellow about the poles. As distillation proceeds, the temperature of the vessel containing the residue of liquid air being allowed to rise slowly, the brightest (green) rays of xenon begin to appear, and the krypton rays soon die out, being superseded by those of xenon. At this stage the capillary part of the sparking-tube is, with a jar in circuit, a brilliant green, and it remains green, though less brilliant, if the jar is removed.

450
Fig. 8.—Apparatus for Fractional Distillation.




Fig. 9.—Apparatus for continuous Spectroscopic Examination.

An improved form of apparatus for the fractionation is represented in fig. 9. The gases to be separated, that is, the least volatile part of atmospheric air, enter the bulb B from a gasholder by the tube a with stop-cock c. B, which is maintained at a low temperature by being immersed in liquid hydrogen, A, boiling under reduced pressure, in turn communicates through the tube b and stop-cock d with a sparking-tube or tubes f, and so on through e with a mercurial pump. To