‘‘(A) IN GENERAL.—Single package vertical air conditioners and single package vertical heat pumps manufactured on or after January 1, 2010, shall meet the following standards: ‘‘(i) The minimum energy efficiency ratio of single package vertical air conditioners less than 65,000 Btu per hour (cooling capacity), single-phase, shall be 9.0. ‘‘(ii) The minimum energy efficiency ratio of single package vertical air conditioners less than 65,000 Btu per hour (cooling capacity), 3-phase, shall be 9.0. ‘‘(iii) The minimum energy efficiency ratio of single package vertical air conditioners at or above 65,000 Btu per hour (cooling capacity) but less than 135,000 Btu per hour (cooling capacity), shall be 8.9. ‘‘(iv) The minimum energy efficiency ratio of single package vertical air conditioners at or above 135,000 Btu per hour (cooling capacity) but less than 240,000 Btu per hour (cooling capacity), shall be 8.6. ‘‘(v) The minimum energy efficiency ratio of single package vertical heat pumps less than 65,000 Btu per hour (cooling capacity), single-phase, shall be 9.0 and the minimum coefficient of performance in the heating mode shall be 3.0. ‘‘(vi) The minimum energy efficiency ratio of single package vertical heat pumps less than 65,000 Btu per hour (cooling capacity), 3-phase, shall be 9.0 and the minimum coefficient of performance in the heating mode shall be 3.0. ‘‘(vii) The minimum energy efficiency ratio of single package vertical heat pumps at or above 65,000 Btu per hour (cooling capacity) but less than 135,000 Btu per hour (cooling capacity), shall be 8.9 and the minimum coefficient of performance in the heating mode shall be 3.0. ‘‘(viii) The minimum energy efficiency ratio of single package vertical heat pumps at or above 135,000 Btu per hour (cooling capacity) but less than 240,000 Btu per hour (cooling capacity), shall be 8.6 and the minimum coefficient of performance in the heating mode shall be 2.9. ‘‘(B) REVIEW.—Not later than 3 years after the date of enactment of this paragraph, the Secretary shall review the most recently published ASHRAE/IES Standard 90.1 with respect to single package vertical air conditioners and single package vertical heat pumps in accordance with the procedures established under paragraph (6).’’.

Deadline.

SEC. 315. IMPROVED ENERGY EFFICIENCY FOR APPLIANCES AND BUILDINGS IN COLD CLIMATES.

dkrause on GSDDPC44 with PUBLAW

(a) RESEARCH.—Section 911(a)(2) of the Energy Policy Act of 2005 (42 U.S.C. 16191(a)(2)) is amended— (1) in subparagraph (C), by striking ‘‘and’’ at the end; (2) in subparagraph (D), by striking the period at the end and inserting ‘‘; and’’; and (3) by adding at the end the following: ‘‘(E) technologies to improve the energy efficiency of appliances and mechanical systems for buildings in cold

VerDate Aug 31 2005

07:12 Jan 26, 2009

Jkt 059194

PO 00002

Frm 00279

Fmt 6580

Sfmt 6581

M:\STATUTES\2007\59194PT2.001

APPS10

PsN: 59194PT2