Bromoxynil and Bromoxynil Octanoate (5010)

From Wikisource
Jump to navigation Jump to search
NIOSH Manual of Analytical Methods (1994)
National Institute for Occupational Safety and Health
Bromoxynil and Bromoxynil Octanoate (5010)
2002956NIOSH Manual of Analytical Methods — Bromoxynil and Bromoxynil Octanoate (5010)1994National Institute for Occupational Safety and Health

(1) BROMOXYNIL and (2) BROMOXYNIL OCTANOATE

(1) C7H3Br2NO MW: (1) 276.93 (2) C15 H17 Br2NO2 (2) 403.13 METHOD: 5010, Issue 2

CAS: (1) 1689-84-5 (2) 1689-99-2 EVALUATION: PARTIAL

OSHA : no PEL NIOSH: no REL ACGIH: no TLV

PROPERTIES:

5010

RTECS: (1) DI3150000 (2) DI3325000 Issue 1: 15 May 1989 Issue 2: 15 August 1994

(1) liquid; BP 194 to 195 °C; (2) solid; MP 45 to 47 °C

SYNONYMS: (1): 2,6-dibromo-4-cyanophenol; 3,5-dibromo-4-hydroxybenzonitrile; (2): 2,6-dibromo-4-cyanophenyl octanoate. SAMPLING SAMPLER:

FILTER (2-µm PTFE membrane)

FLOW RATE:

1 to 3 L/min

VOL-MIN: -MAX:

2 L @ 0.1 mg/m 3 400 L

SHIPMENT:

MEASUREMENT TECHNIQUE:

HPLC, UV DETECTION

ANALYTE:

Bromoxynil; Bromoxynil octanoate

EXTRACTION:

3 mL acetonitrile; 60 min

MOBILE PHASE:

acetonitrile/water gradient; 1 mL/min

refrigerated; protect from light

COLUMN:

µ-Bondapack C 18, 25 cm x 4.6 mm-ID reverse phase or equivalent

SAMPLE STABILITY:

at least 25 days @ 4 °C in the dark [1]

DETECTOR:

UV detector @ 254 nm

BLANKS:

2 to 10 field blanks per set

CALIBRATION:

solutions of analytes in acetonitrile

RANGE:

2 to 30 µg per sample [1]

ESTIMATED LOD: (1) 0.6 and (2) 0.3 µg per sample [1] ACCURACY PRECISION (Sr): RANGE STUDIED:

not studied

BIAS:

none identified

(1) 0.011 @ 18 µg per sample [1] (2) 0.042 @ 35 µg per sample [1]

ˆ ): not evaluated OVERALL PRECISION (S rT ACCURACY:

not determined

APPLICABILITY: The working range is 0.02 to 0.3 mg/m 3 for a 100-L air sample. This method permits the simultaneous determination of both analytes.

INTERFERENCES: None known. Both analytes photodecompose.

OTHER METHODS: A gas chromatographic method has been described [2].

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94 BROMOXYNIL and BROMOXYNIL OCTANOATE: METHOD 5010, Issue 2, dated 15 August 1994 - Page 2 of 3

REAGENTS: 1. 2. 3. 4. 5.

EQUIPMENT:

Bromoxynil. Bromoxynil octanoate. Acetonitrile, HPLC grade. Water, distilled, deionized. Calibration stock solution, 1 mg/mL. Dissolve 0.100 g each of Bromoxynil and Bromoxynil octanoate in acetonitrile; dilute to 100 mL in a volumetric flask. Prepare daily, in duplicate.

1. Sampler: PTFE-coated glass fiber (Pallflex T60A20) or 2-µm PTFE membrane (GHIA), 37-mm diameter. (Filters commercially available). NOTE: Use opaque or light-protected cassette filter holder. 2. Personal sampling pump, 1 to 3 L/min, with flexible connecting tubing. 3. Jars, ointment, 60-mL, squat form, with PTFElined screw caps. 4. Volumetric flasks, 10- and 100-mL 5. Pipet, 3-mL. 6. Vials (for autosampler). 7. Liquid chromatograph with gradient capability, UV detector (254 nm) and column, (see page 5010-1). 8. Syringes, 5-mL. 9. Syringe filters, PTFE; or Swinnex adaptor with luer fitting containing 0.5-µm PTFE filter, 13-mm.

SPECIAL PRECAUTIONS: None.

SAMPLING: 1. 2. 3.

Calibrate each personal sampling pump with a representative sampler in line. Sample at an accurately known flow rate between 1 and 3 L/min for a total sample size of 20 to 400 L. Do not exceed 2 mg total dust loading on filter. After sampling, cap the filter holders, ship at 4 °C and protect from light.

SAMPLE PREPARATION: 4. 5.

Transfer the filter to a jar. Add 3.0 mL acetonitrile and desorb with occasional swirling for at least 1 h. Filter an aliquot through a PTFE syringe filter or a 0.5-µm PTFE filter using a syringe with a Swinnex adaptor to remove particulate. Transfer the aliquot to a sample vial and seal.

CALIBRATION AND QUALITY CONTROL: 6.

Calibrate daily with at least six working standards over the range 0.6 to 30 µg of both analytes per sample. a. Add known amounts of calibration stock solution to acetonitrile in 10-mL volumetric flasks and dilute to the mark. b. Analyze together with samples and blanks (steps 11 and 12). c. Prepare calibration graph (peak area vs. µg analyte). NOTE: Before processing any samples, demonstrate, through the analysis of a solvent blank, that all glassware and reagents are interference-free. Each time a new set of samples is analyzed or there is a change in reagents, process a solvent blank as a safeguard against chronic laboratory contamination. NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94 BROMOXYNIL and BROMOXYNIL OCTANOATE: METHOD 5010, Issue 2, dated 15 August 1994 - Page 3 of 3

MEASUREMENT: 7.

8.

9.

Set the liquid chromatograph to the conditions on page 5010-1 using the following mobile phase gradient: 50% CH 3CN/50% H 2O for 10 min; 10 min gradient to 100% CH 3N; hold 10 min; 2 min gradient to 50% CH 3CN/50% H 2O; hold 15 min. Inject 100 µL sample extract with a high-pressure syringe or a sampling loop. Record the volume injected to the nearest 0.5 µL. Under these conditions, the retention times are 3.6 min for Bromoxynil and 33 min for Bromoxynil octanoate. Measure peak area. NOTE: If the peak area exceeds the linear range of the system, dilute with acetonitrile and reanalyze. If the peak area measurement is hindered by the presence of interferences, other chromatographic conditions may be required.

CALCULATIONS: 10. 11.

Read the mass of analytes (including appropriate aliquot factors) in the sample extract, W (µg), and average media blank, B (µg), from the calibration graph. Determine the concentrations, C (mg/m 3), of each analyte in the air volume sampled, V (L):

EVALUATION OF METHOD: This method was developed with laboratory samples during the period June to September, 1983 [1]. PTFE-coated glass fiber filters were spiked with 50 µg Bromoxynil and 90 µg Bromoxynil octanoate, after which 90 L of clean air at 80% RH was drawn through the filters. Recoveries averaged 93% for Bromoxynil and 100% for Bromoxynil octanoate with relative standard deviations, Sr, of 0.046 and 0.020, respectively. Storage at ambient conditions for 14 days gave recoveries of 70 to 80% for both compounds, while storage under refrigeration for 25 days or at ambient conditions for two days followed by refrigeration for 23 days gave recoveries in the range 95 to 98%.

REFERENCES: [1] [2]

Arthur D. Little, Inc., Backup Data Report prepared under NIOSH Contract 200-82-2528 (unpublished, October 7, 1983). Thrun, K., J. Harris, and V. Grady. "Sampling and Analysis Procedures for Pesticide Manufacturing Wastes," Report, EPA Contract No. 68-02-3111 (1982).

METHOD WRITTEN BY: K. T. Menzies, K. J. Beltis, A. C. Roche, Arthur D. Little, Inc.; and B. R. Belinky, NIOSH/DPSE.

NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94