II. Detailed Guidelines for Use

should be used only in workplaces free of oil aerosols. Filters passing DOP oil tests (i-e., R- and P-series filters) are resistant to efficiency degradation and can be used for protection against any aerosols (including oil-based particulates) in the workplace.

D. USE LIMITATIONS

The service life of filters in all three categories of filter efficiency degradation (i.e., N-, R-, and P-series) is limited by considerations of hygiene, damage, and breathing resistance. All filters should be replaced whenever they are damaged, soiled, or causing noticeably increased breathing resistance (e.g., causing discomfort to the wearer).

R- or P-series filters can be used for protection against oil or non-oil aerosols. N-series filters should be used only for non-oil aerosols. Use and reuse of the P-series filters would be subject only to considerations of hygiene, damage, and increased breathing resistance. Generally, the use and reuse of N-series filters would also be subject only to considerations of hygiene, damage, and increased breathing resistance. However, for dirty workplaces that could result in high filter loading (i.e., 200 mg), service time for N-series filters should only be extended beyond 8 hours of use (continuous or intermittent) by performing an evaluation in specific workplace settings that demonstrates (a) that extended use will not degrade the filter efficiency below the efficiency level specified in Part 84, or (b) that the total mass loading of the filter(s) is less than 200 mg. The R-series filters should be used only for a single shift (or for 8 hours of continuous or intermittent use) when oil is present. However, service time for the R-series filters can be extended using the same two methods described above for N-series filters. These determinations would need to be repeated whenever conditions change or modifications are made to processes that could change the type of particulate generated in the user’s facility.

E. PARTICULATE RESPIRATOR SELECTION

To select the correct respirator for protection against particulates, the following conditions must be known:

  • The identity and concentration of the particulates in the workplace air
  • The OSHA or MSHA permissible exposure limit (PEL), the NIOSH recommended exposure limit (REL), or other occupational exposure limit for the contaminant
  • The hazard ratio (HR) (i.e., the airborne particulate concentration divided by the exposure limit)