Page:NIOSH Hazard review of Carbonless Copy Paper.pdf/104

From Wikisource
Jump to navigation Jump to search
This page has been proofread, but needs to be validated.
4 HEALTH EFFECTS

Table 4–12 (Continued). Analysis of repeated insult patch test (RIPT) studies submitted by industry clients in response to 1987 and 1997 Federal Register notices on CCP and its components
Study year Report
number*
Laboratory Test material Response
rate
Score No. of
subjects
with
score
Classification
as irritant
(Y/N)§,¶
Current use of material
79–0085–73 (continued) G. Code 94 CB, ruptured capsule 2/151   N
2 1
4 1
H. Code 94 CB, capsules not ruptured 1/151 4 1 N
1979 79–0246–73 Hill Top Research, Inc. A. CF surface colored 2/136   N Test materials discontinued in mid-1980s
1 1
4 1
B. CF surface uncolored 2/136   N
3 1
4 1
C. CB surface, ruptured capsules 1/136 2 1 N
D. CB, unruptured capsules, code 95 2/136   N
1 1
4 1
E. CF colored 2/136 1 2 N
F. CF uncolored 1/136 4 1 N
G. CB ruptured capsules, code 96 2/136   N
1 1
2 1

________________
See footnotes at end of table.

(Continued)
Carbonless Copy Paper
83