of the melting point of tin, 228° C, being rarely reached in good generators where these conditions are met.
Undoubtedly the best generators, and the only ones which from a scientific point of view should be employed, are those of class III, in which carbide falls into an excess of water. In such generators it is impossible to get a temperature higher than the boiling point of water, 100° C, while with a properly arranged tank the temperature never exceeds that of the air by more than a few degrees. Under these conditions the absence of polymerization and the washing of the nascent and finely divided bubbles of gas by the limewater in the generator yield acetylene of a degree of purity unapproached by any other form of generator.
When acetylene is burned in air under such conditions that the flame does not smoke, it has been proved by Gréhant that there is no carbon monoxide among the combustion products; the acetylene combines with the oxygen of the air to form carbon dioxide and water (C2H2 + 5O = 2CO2 + H2O). One cubic foot of acetylene requires two and a half cubic feet of oxygen. Supposing a room to have an illumination equal to sixty-four standard candles; this amount of light from candles would use up 38.5 cubic feet of oxygen from the air, and would give off forty-three cubic feet of carbon dioxide; petroleum requires, in cubic feet, twenty-five of oxygen, and gives off forty of carbon dioxide; gas burned with a flat flame requires about twenty-five oxygen and gives nineteen carbon dioxide—with an Argand flame a little less, while with the Welsbach burner gas requires only three oxygen, and gives off 1.8 carbon dioxide; acetylene requires five oxygen and yields four carbon dioxide. So that, light for light, acetylene fouls the air less than any ordinary illuminant excepting the Welsbach gas burner. (With incandescent electric light there is no combustion and no fouling of the air.)
Under the best conditions five cubic feet of acetylene give a light of two hundred and forty candles for one hour, or we may speak of acetylene as a two-hundred-and-forty-candle gas. Yet this statement, though strictly true, may be misleading. When ordinary illuminating gas is tested with the photometer, it is burned from a standard flat-flame burner, burning five cubic feet per hour. Now the amount of light given by such a gas flame is no greater than is pleasant to the eye; it is true that if we burn five cubic feet of acetylene from a suitable flat-flame burner, a light of two hundred and forty candles is given, but it is unfair to take this ratio as representing the actual relative illuminating value of the two lights, because we neither need a light of two hundred and forty candles, nor is such an amount of light issuing from one burner endurable to the eye. One-foot or one-half foot acetylene burners are used for domestic lighting;